Abb Differential Block DDA 202 63A 2P Type B 300mA B273242


ABB B273242 8012542732426

Abb differential lock DDA 202 series:

  • Rated current 63 Amps
  • 2 Poles
  • Type B
  • Rated residual current: 300mA
  • Power supply 230...230V
  • Rated insulation voltage 500V
  • Rated frequency 50/60 Hz
  • Power loss: 5W

DDA 200 differential blocks can be coupled with the circuit breakers of the S 200 L, S 200, S 200 M, and S 200 P series to realize the magnetothermal differential protection function.

Do you have questions about this product or did you not find what you were looking for? Ask us!

Abb Differential Block DDA 202 63A 2P Type B 300mA B273242

€347.45
€347.45

Abb Differential Block DDA 202 63A 2P Type B 300mA B273242

€347.45
Tax included

Abb Differential Block DDA 202 63A 2P Type B 300mA B273242

€347.45

Buy it within and receive it from Tuesday, 17 December
Two-year warranty
Easy return within 14 days

It is possible to couple the DDA 200 with magnetic-only circuit breakers of the M 200 series, in which case additional thermal type protection must be provided for protection against overload currents.

Type B differential blocks: reliable in any fault situation The detection of fault currents with continuous waveform or high frequency. They were developed for the detection of fault currents with continuous waveform or high frequency.


Types B are suitable in all cases where fault currents with a waveform similar to the continuous waveform or with frequency values and harmonic content such that the correct tripping of types A is not guaranteed, namely, in the presence of:

  • Three-phase AC/DC converters where in the absence of double insulation faults may occur in the DC part of the circuit (downstream of the rectifier)
  • Three-phase frequency converters where the ground fault current may be high frequency or high harmonic contribution
  • Three-phase UPS uninterruptible power supplies where in the absence of double insulation, insulation defects may occur in the DC portion of the circuit (downstream of the rectifier)
  • Electromedical equipment where there are devices powered in DC by an AC/DC converter inside the equipment
  • Photovoltaic systems without at least a simple separation between the AC side and the DC side.
  • Charging stations for electric vehicles with three-phase power supply

Characteristics:

  • Connection capacities: Rigid 25 ... 25 mm² - Flexible 25 ... 25 mm²
  • Ambient temperature: -25 to 55 °C
  • Ambient temperature: Operating -25...55 °C
  • Degree of protection: IP2X
  • Short-circuit current rating (SCCR): 0.3 ... 0.3 A
  • Dimensions Product width: 105 mm - Product height: 93 mm - Product depth: 76 mm
  • Product net weight: 0.290 kg

Data sheet

Voltage:
230VAC
Modules:
4
Poles:
2P
RCD Type:
B
Differential current :
0.3A
Amps:
63A
Circuit Protections:
Earth Leakage add-on Blocks