Haier MP Ducted Air Conditioner 5.0kW 18000BTU R32 A++ WiFi
Haier Medium Pressure Inverter Ducted Air Conditioner 5.0kW 18000BTU with R32 Gas, Energy Class A++, Kit consisting of:
- 1 indoor unit (AD50S2SM3FA (H) - 2501655D2)
- 1 outdoor unit (1U50S2SJ2FA-2 - 2502305V2)
Accessory to be purchased separately Wired control YR-E17A with daily timer (25030106L), or Infrared remote control YR-HQS01 (25030003L).
Wi-Fi control with App hOn to remotely control the air conditioner.
Haier MP Ducted Air Conditioner 5.0kW 18000BTU R32 A++ WiFi
Tax included
FEATURES:
- Low noise level
- UV-C Protection Technology UV-C Lamp Purification
- Compact design
- On-Off card
- Condensate drain pump
- Installation flexibility.
QUIETNESS
The use of DC Inverter fans and design optimization decrease the noise level of indoor units. Optimized airflow ensures that the air conditioner is as quiet as possible. Does the noise caused by your air conditioner bother you? Haier air conditioners have an advanced noise control system with an optimized design of air ducts and cross-flow fan.
Specifications:
Cooling:
- Rated rated capacity Min/Max: 5.0 KW (1.8-6.0)
- Rated input power: Min/Max kW 1.55 (0.55-2.00)
- SEER 6.10
- Energy class: A++
- EER 3.23
- Indicative annual energy consumption kW/a 291
Heating:
- Rated capacity Min/Max: KW 6.0 (2.0-6.2)
- Rated input power Min/Max 1.48 (0.6-2.00)
- SCOP: 3.8
- Seasonal energy efficiency class A
- COP 3.71
- Indicative annual energy consumption: kWh/a 1782
Indoor Unit Features:
- Dimensions: (WxDxH) 1100x700x248mm
- Weight 31Kg
- Treated air cubic meters/h (H / M / L) 1020/900/780/550
- Dehumidification capacity l/hr 1.8
- sound pressure level (Cooling) dBa 43/37/30/28
- Sound pressure level (Heating) dBa 43/37/30/28
- Sound Power Level Cooling dBA 56
- Sound power level Heating dBA 56
Outdoor Unit Features:
- Dimensions: (WxDxH) 820x338x614mm
- Weight 37.8Kg
- Sound Pressure Level dBa 51
- Sound Power Level dBA 63
- Power supply Single phase 220-240 / 50Hz
- Current Consumption Max 10.9A
- Compressor type Inverter twin rotary
- Compressor brand Mitsubishi
Hydraulic data:
- Liquid piping 6.35 (1/4")
- Gas piping 12.7 (1/2)
- Std piping length without additional refrigerant charge 7 meters
- Max/min piping length 25/3 meters
- Max height difference between indoor/outdoor unit 15 meters
- Refrigerant Type: R32 gas
- Factory refrigerant charge 0.95 kg
- Tons of CO2 equivalent tCO2EQ 0.64
- Additional ref. charge over std length 20 g/m
- Operating limits RAFF. min~max °C 21÷35°C (in) / -10÷46°C (out)
- RISC. operating limits min~max °C 10÷27°C (in) / -15÷24°C (out)
Data sheet
- Air conditioners:
- Ducted
- Gas:
- R32
- Power:
- 18000 BTU (5,0 Kw)
- WIFI:
- Integrated
- Room Size:
- 55m²
- Energy class:
- A++