Hiltron DG12 dual technology detector


C1A DG12 8056450410335

Hiltron passive infrared and microwave dual technology detector with the following features:

  • Dual-element digital sensor (Digipyro™).
  • Microwave sensor 10,525Gh
  • Complete with anti-disorientation joint
  • Adjustable sensitivity through trimmer
  • Tamper protection
  • Tamper function
  • Anti-masking function
  • High immunity to RF (over 30Vm)
  • Rated supply voltage 12V
  • Maximum absorption 18mA
  • Coverage: 12 meters
Do you have questions about this product or did you not find what you were looking for? Ask us!

Hiltron DG12 dual technology detector

€23.37
€23.37

Hiltron DG12 dual technology detector

€23.37
Tax included

Hiltron DG12 dual technology detector

€23.37

Buy it within and receive it from Monday, 11 November
Two-year warranty
Easy return within 14 days
Other Features:
  • Hiltron series
  • Lens beams 23 (on 3 horizontal levels)
  • Angle of coverage front (PIR) H: 120°; V: 60°.
  • Microwave frontal coverage angle H: 80°; V: 32°.
  • Signaling LED
  • Solid state relay output NC 100mA, 50VDC max
  • Initial stabilization time 30"
  • Security grade: 1
  • Environmental class: 2
  • Dimensions (WxHxD) 59x99x60mm
  • Complies with CEI EN 50131-1 standards

OPERATION: The DG12 works in "dual technology", which means that only if both technologies (Infrared and Microwave) reveal a real intrusion is given the alarm. This allows you to avoid false alarms due to the activation of the infrared sensor only (sometimes caused eg. by sunlight) or the microwave sensor only (sometimes caused eg. by moving objects).

ANTIMASCHERAMENTO: The DG12 in case of prolonged alarm of one of the two technologies, and in the absence of detection of the other, activates a continuous alarm status, indicated by the red LED flashing and the zone contact open, a state that remains until both technologies do not resume proper operation. In this way, if you mask, for example, the infrared sensor thermally isolating, but continues to repeatedly alarm the microwave sensor, the detector is placed in a state of continuous alarm that triggers the alarm control panel.

ANTIMANOMISSION: If the DG12 detects a presence very close to the detector (about 40cm) is placed in a state of continuous alarm, indicated by flashing red LED and the opening of the zone contact. Even in this case, if after a few seconds, both technologies resume to detect presence at greater distance, and then are normally operating, the detector resumes its normal operation.

INSTALLATION:
  • Remove the electronic circuit from the container, levering it sideways with a tool and hook the joint to the base of the container after passing it through the fixing ring.
  • Use the extension for the joint in case of ceiling mounting.
  • Cover the unused hole on the base of the with the supplied mat.
  • Fix the base of the joint on a smooth and flat surface not subject to vibrations, covering the hole for the passage of electrical cables for connection to the central unit, using the plugs provided.
  • Pass the electrical cables through the hole of the joint and hook the fixing ring to the base.
  • Once installed and oriented in the desired position, it will be possible to lock the detector by fully rotating the locking ring.
  • Reposition the circuit on the base of the container and make the electrical connections.
  • It is possible to mount the detector at an angle (in this case do not use the joint, but drill two holes on the container for fixing on the sides.
  • Do not direct the detector towards objects that could produce rapid temperature changes such as radiators, electric radiators, air conditioners, open flames, etc..
  • Also avoid installation near them.
  • Do not partially or completely obscure the detector's field of view.