Telemecanique contactor TeSys D 18A 3P 220VAC LC1D18M7
SNR LC1D18M7
3389110349504
Telemecanique Schneider LC1D contactor, with the following characteristics:
- Number of poles: 3
- Power pole contact composition: 3 NO
- Control circuit type: AC at "50/60 Hz".
- Control voltage [Uc]: 220 V "AC" "50/60 Hz".
- Auxiliary contact composition: 1 NO + 1 NC
- Rated impulse withstand voltage [Uimp]: 6 kV according to IEC 60947
- Overvoltage category: Acti9 VigiARC iC40
- Conventional open air thermal current [Ith]: 10A at <60°C for signaling circuit, 32A at <60°C for power circuit
- Rated Interrupting Capacity: 300A at 440V for IEC 60947 compliant Power Circuit
Telemecanique contactor TeSys D 18A 3P 220VAC LC1D18M7
€43.92
€43.92
Telemecanique contactor TeSys D 18A 3P 220VAC LC1D18M7
€43.92
Tax included
Tax included
Items Available: 37
Telemecanique contactor TeSys D 18A 3P 220VAC LC1D18M7
€43.92
Buy it within and receive it from Monday, 11 November
Other Features:
- Average impedance: 2.5 mOhm "50 Hz" - Ith 32A per Power Circuit.
- Operating time: 12...22 ms closing, 4...19 ms opening
- Mechanical life: 15 Mccycles
- Maximum operating speed: 3600 cycles/h at <60 °C
- Coil technology: without integrated suppressor module
- Heat dissipation: 2...3 W at 50/60 Hz
- Auxiliary contacts type: mechanical connection type 1 NO + 1 NC according to IEC 60947-5-1, mirror contact type 1 NC according to IEC 60947-4-1
- Signaling frequency: 25...400 Hz
- Minimum switching current: 5 mA per signaling circuit
- Minimum switching voltage: 17V per signaling circuit
- Non-overlapping time: 1.5 ms on deactivation between NC and NO contact, 1.5 ms on activation between NC and NO contact
- Insulation resistance: > 10 MOhm for signaling circuit
- IP degree of protection: IP20 Front side complies with IEC 60529
- Climatic sealing: Conforms to IACS E10, conforms to IEC 60947-1 Annex Q category D
- Treatment of protection: TH in accordance with IEC 60068-2-30
- Pollution degree: 3
- Operating ambient temperature: -40/+60 °C, 60/+70 °C with derating
- Storage temperature: -60/+80 °C
- Operating altitude: 0...3000 m
- Fire resistance: 850 °C in accordance with IEC 60695-2-1
Rated operational current [Ie]:
- 18 A 60 °C) "AC" AC-3 for Power Circuit at <= 440V
- 32 A 60 °C) "AC" AC-1 for <= 440V power circuit
- 18 A 60 °C) AC-3e "AC" for power circuit at <= 440V
Motor Power [kW]:
- 4 kW at 220...230V "AC" "50/60 Hz" (AC-3)
- 7.5 kW @ 380...400V "AC" "50/60 Hz" (AC-3)
- 9 kW @ 415...440V 'AC' '50/60Hz' (AC-3)
- 10 kW @ 500V 'AC' '50/60Hz' (AC-3)
- 10 kW @ 660...690V 'AC' '50/60 Hz' (AC-3)
- 4 kW @ 400V 'AC' '50/60Hz' (AC-4)
- 4 kW @ 220...230V 'AC' '50/60Hz' (AC-3e)
- 7.5 kW @ 380...400V 'AC' '50/60Hz' (AC-3e)
- 9 kW @ 415...440V 'AC' '50/60Hz' (AC-3e)
- 10 kW @ 500V "AC" "50/60 Hz" (AC-3e) 10 kW @ 660...690V "AC" "50/60 Hz" (AC-3e)
Motor Power HP (UL / CSA):
- 1 hp at 115 V for 1 phase motors "AC" "50/60 Hz"
- 3 hp at 230/240 V for 1 phase "50/60 Hz" AC motors
- 5 hp at 200/208 V for 3 phase "50/60 Hz" AC motors
- 5 hp at 230/240 V for 3 phase "50/60 Hz" AC motors
- 10 hp at 460/480 V for 3-phase "50/60 Hz" AC motors
- 15 hp at 575/600 V for 3 phase "50/60 Hz" AC motors
Rated Closing Power Irms:
- 140 A "AC" for IEC 60947-5-1 compliant signaling circuit
- 250 A DC for IEC 60947-5-1 compliant signaling circuit
- 300 A at 440 V for IEC 60947-compliant power circuit
Rated short-time withstand current [Icw]:
- 145 A at <40 °C - 10 s for Power circuit
- 240 A @ <40°C - 1 s for Power Circuit
- 40 A at <40 °C - 10 min for Power Circuit
- 84 A at <40 °C - 1 min for Power Circuit
- 100 A - 1 s per signaling circuit
- 120 A - 500 ms per signaling circuit
- 140 A - 100 ms per signaling circuit
Associated Fuse Gauge
- 10 A gG per IEC 60947-5-1 compliant signaling circuit
- 50 A gG at <= 690 V Type 1 coordination for Power Circuit
- 35 A gG at <= 690 V Type 2 coordination for Power Circuit
Rated insulation voltage [Ui]:
- 690 V complying with IEC 60947-4-1 Power Circuit:
- 600 V CSA certified Power circuit:
- 600 V UL certified Power circuit:
- 690 V complying with IEC 60947-1 signaling circuit:
- 600 V CSA certified Signaling circuit:
- 600 V UL certified signaling circuit:
Electrical durability:
- 1.65 Mccycles 18 A AC-3 at Ue <= 440V
- 1 Mcicli 32 A AC-1 to Ue <= 440V
- 1.65 Mcicles 18 A AC-3e at Ue <= 440V
Power Dissipation Per Pole
- 2.5 W AC-1
- 0.8 W AC-3
- 0.8 W AC-3e
Connections - terminals
- Control circuit: Screw terminals 1 cable 1...4 mm²flexible without cable termination
- Control circuit: screw terminals 2 cables 1...4 mm²flexible without cable termination
- Control circuit: screw terminals 1 cable 1...4 mm²flexible with cable termination
- Control circuit: screw terminals 2 wires 1...2.5 mm²flexible with cable termination
- Control circuit: screw terminals 1 wire 1...4 mm² solid without cable termination
- Control circuit: screw terminals 2 wires 1...4 mm² solid without cable termination
- Power circuit: screw terminals 1 cable 1.5...6 mm²flexible without cable termination
- Power circuit: screw terminals 2 cables 1.5...6 mm²flexible without cable termination
- Power circuit: screw terminals 1 cable 1...6 mm²flexible with cable termination
- Power circuit: screw terminals 2 wires 1...4 mm²flexible with cable termination
- Power circuit: screw terminals 1 cable 1.5...6 mm² solid without cable termination
- Power circuit: screw terminals 2 wires 1.5...6 mm²solid without cable termination
Tightening torque:
- Power circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6 mm
- Power circuit: 1.7 Nm - on screw terminals - with Philips screwdriver No 2
- Control circuit: 1,7 Nm - on screw terminals - with flat screwdriver Ø 6 mm
- Control circuit: 1.7 Nm - on screw terminals - with Philips screwdriver No 2
- Control circuit: 1,7 Nm - on screw terminals - with pozidriv screwdriver No 2
- Power circuit: 2,5 Nm - on screw terminals - with pozidriv screwdriver No 2
Reliability level safety
- B10d = 1369863 cycles Contactor with rated load in accordance with EN/ISO 13849-1
- B10d = 20000000 cycles Contactor with mechanical load according to EN/ISO 13849-1
Control circuit voltage limits
- 0.3...0.6 Uc -40...70 °C "AC" de-energizing 50/60 Hz
- 0.8...1.1 Vac -40...60 °C Operating AC 50 Hz
- 0.85...1.1 Uc -40...60 °C operating "AC" 60 Hz
- 1...1.1 Uc 60...70 °C operating "AC" 50/60 Hz
Inrush power in VA
- 70 VA 60 Hz 0.75 20 °C)
- 70 VA "50 Hz" 0.75 20 °C)
Holding power consumption VA
- 7.5 VA 60 Hz 0.3 20 °C)
- 7 VA "50 Hz" 0.3 20 °C)
Mechanical robustness:
- Open contactor vibration: 2 Gn, 5...300 Hz
- Closed contactor vibrations: 4 Gn, 5...300 Hz
- Open contactor shocks: 10 Gn per 11 ms
- Closed contactor shocks: 15 Gn per 11 ms
Dimensions and weight:
- height 77 mm
- Width 45 mm
- depth 86 mm
- Weight 0,33 kg
Data sheet
- Type:
- Contactors
- Voltage:
- 220VAC
- Poles:
- 3P
- Degree of protection:
- IP20