Telemecanique Contactor TeSys D 9A 3P 24VDC LC1D09BL


SNR LC1D09BL 3389110361070

Schneider TeSys LC1D contactor with the following characteristics:

  • Number of poles: 3
  • Rated use voltage Ue: <= 690 V "AC" 25...400 Hz Power circuit - <= 300 V DC Power circuit
  • Rated use current Ie: 9 A 60 °C) "AC" AC-3 for Power circuit at <= 440 V - 25 A 60 °C) "AC" AC-1 for Power circuit at <= 440 V - 9 A 60 °C) "AC" AC-3e for Power circuit at <= 440 V
  • Contact pole composition: 3 NO
  • Contact compatibility: M5
  • Auxiliary contact composition: 1 NO + 1 NC
  • Rated impulse withstand voltage: 6 kV in accordance with IEC 60947
Do you have questions about this product or did you not find what you were looking for? Ask us!

Telemecanique Contactor TeSys D 9A 3P 24VDC LC1D09BL

€53.95
€53.95

Telemecanique Contactor TeSys D 9A 3P 24VDC LC1D09BL

€53.95
Tax included

Telemecanique Contactor TeSys D 9A 3P 24VDC LC1D09BL

€53.95

Buy it within and receive it from Thursday, 12 December
Two-year warranty
Easy return within 14 days

TeSys' D contactor, 3-pole (3NO), for motor control applications up to 9 A/690V AC-3 (4 kW at 400 V). Features a low-power 24V DC coil with transient suppressor module, built-in 1NO+1NC auxiliary contacts (mirror NC certified), connection via screw terminals. For operating speeds up to 3600 cycles/hour and environments up to 60°C, Features high reliability and durability. Compact (width 45mm), DIN rail mounting or screw mounting. Certified according to various standards (IEC, UL, CSA, CCC, EAC), Green Premium compliance (RoHS/REACh).


Motor power:

  • 2.2 kW at 220...230 V "AC" "50/60 Hz" (AC-3)
  • 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3)
  • 4 kW at 415...440 V "AC" "50/60 Hz" (AC-3)
  • 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3)
  • 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3)
  • 2.2 kW at 400 V "AC" "50/60 Hz" (AC-4)
  • 2.2 kW at 220...230 V "AC" "50/60 Hz" (AC-3e)
  • 4 kW at 380...400 V "AC" "50/60 Hz" (AC-3e)
  • 4 kW at 415...440 V "AC" "50/60 Hz" (AC-3e)
  • 5.5 kW at 500 V "AC" "50/60 Hz" (AC-3e)
  • 5.5 kW at 660...690 V "AC" "50/60 Hz" (AC-3e)


Motor power in hp:

  • 1 hp at 230/240 V for 1 phase motors "AC" "50/60 Hz"
  • 2 hp at 200/208 V for 3 phase motors "AC" "50/60 Hz"
  • 2 hp at 230/240 V for 3 phase motors "AC" "50/60 Hz"
  • 5 hp at 460/480 V for 3 phase motors "AC" "50/60 Hz"
  • 7.5 hp at 575/600 V for 3 phase motors "AC" "50/60 Hz"
  • 0.33 hp at 115 V for 1 phase motors "AC" "50/60 Hz"


Rated insulation voltage:

  • 690 V complying with IEC 60947-4-1 Power circuit.
  • 600 V CSA certified Power circuit
  • 600 V UL certified Power circuit
  • 690 V complying with IEC 60947-1 signaling circuit
  • 600 V CSA certified signaling circuit
  • 600 V UL certified signaling circuit


Characteristics:

  • Conventional thermal current in open air: 25 A at <60 °C for Power circuit - 10 A at <60 °C for signaling circuit
  • Rated closing capacity Irms: 250 A at 440 V per IEC 60947-compliant Power circuit - 140 A "AC" per IEC 60947-5-1-compliant signaling circuit - 250 A DC per IEC 60947-5-1-compliant signaling circuit
  • Rated breaking capacity: 250 A at 440 V per IEC 60947-compliant power circuit
  • Associated fuse rating: 10 A gG for signaling circuit complying with IEC 60947-5-1, 25 A gG at <= 690 V Type 1 coordination for Power circuit, 20 A gG at <= 690 V Type 2 coordination for Power circuit
  • Time constant: 40 ms
  • Minimum switching current: 5 mA per signaling circuit
  • Minimum switching voltage: 17 V per signaling circuit
  • No-overlap time: 1.5 ms upon deactivation between NC and NO contact - 1.5 ms upon activation between NC and NO contact
  • Inrush power in W: 2.4 W 20 °C)
  • Holding power consumption W: 2.4 W at 20 °C
  • Insulation resistance: > 10 MOhm per signaling circuit
  • Dimensions: height 77 mm - width 45 mm - depth 95 mm
  • Weight: 480 grams

Data sheet

Type:
Contactors
Voltage:
24V
Poles:
3P
Degree of protection:
IP20