Sick photoelectric energy sensor VTE180-2P42482 M18 6041811

Sick photoelectric energy sensor VTE180-2P42482 M18 6041811


SIK 6041811

Sick energy photoelectric sensor, with the following characteristics:

  • Supply voltage: 10 V DC ... 30 V DC
  • Residual ripple: ± 10 %
  • Current consumption: 30 mA
  • PNP switching output
  • Switching type: light on/dark on operation
  • Selectable switching mode: Selectable via L/D control cable
  • Signal voltage PNP HIGH/LOW: Approx. UV - 1.8 V / 0V
  • Output current Imax. ≤ 100 mA
  • Response time: ≤ 0.5 ms
  • Switching frequency: 1,000 Hz
  • Connection type: M12 male connector, 4-pin
  • Protection class: III
Do you have questions about this product or did you not find what you were looking for? Ask us!
Sick photoelectric energy sensor VTE180-2P42482 M18 6041811

Sick photoelectric energy sensor VTE180-2P42482 M18 6041811

€104.90
€104.90

Sick photoelectric energy sensor VTE180-2P42482 M18 6041811

€104.90
Tax included

Sick photoelectric energy sensor VTE180-2P42482 M18 6041811

€104.90

Buy it within and receive it from Wednesday, 13 November
Two-year warranty
Easy return within 14 days

Other technical features:

  • Housing material Metal, nickel-plated brass and PC
  • Material, optics Plastic, PMMA
  • Degree of protection: IP67
  • Scope of supply: fixing nut (2 x)
  • Operating ambient temperature -25/+55 °C
  • Ambient storage temperature: -40/+70 °C
  • Dimensions (W x H x D): 18 mm x 18 mm x 69.8 mm
  • Light emission point: cylindrical
  • Length: 69.8 mm
  • Thread diameter (Housing): M18 x 1
  • Optical axis: Axial
  • Max. sensing distance: 1 mm ... 1,100 mm
  • Sensing distance: 1 mm ... 800 mm
  • Nature of light: Visible red light
  • Light source: LED
  • Light spot size (distance): Ø 30 mm (800 mm)
  • Irradiance angle About 1.2°
  • Wavelength: 645 nm
  • Setting: potentiometer, 270° (Sensing distance)

Data sheet

Type:
Sensors
Degree of protection:
IP67