CPR cable FS18OR18 4 G 1 mmq 300/500V Cca-s3 d1 a3
CPR FS18OR18 4 G 1 mmq 300/500V cable (replaces the old Fror) Power, signaling and control cable, insulated with S18-quality PVC under R18-quality PVC sheath, with special fire reaction characteristics and complying with the Construction Products Regulation CPR (EU) No. 305/11.
Suitable for fixed installation or temporary installation in places with fire hazards. For indoor use in dry or wet rooms.
Diameter: 6.7 mm
Sold by the meter.
- Baldassari cavi
- Icel
- La Triveneta
- Prysmian
CPR cable FS18OR18 4 G 1 mmq 300/500V Cca-s3 d1 a3
CPR cable FS18OR18 4 G 1 mmq 300/500V Cca-s3 d1 a3
Tax included
CPR cable FS18OR18 4 G 1 mmq 300/500V Cca-s3 d1 a3
Features:
- Conductor Flexible annealed red copper rope, class 5
- Insulation PVC compound of S18 quality
- Outer sheath R18-quality PVC compound
- Sheath color Brown
- Rated voltage Uo/U: 300/500 V
- Maximum operating temperature: 70°C
- Minimum operating temperature: -15°C (in the absence of mechanical stress)
- Minimum laying temperature: 0°C
- Maximum short circuit temperature: 160°C
- Maximum tensile stress: 50 N/mm2
- Minimum bending radius: 4 times the maximum outer diameter
Application: Suitable for fixed laying or temporary installation in places with fire hazards. For indoor use in dry or wet rooms.
The FS18OR18 cables belong to the AFIAM line and are marked Cca-s3,d1,a3, to indicate that they comply with the Construction Products Regulation (CPR) in accordance with the requirements prescribed in EN 50575:2014+A1:2016 and to indicate that they are of the non-fire propagating type in accordance with the self-extinguishing requirements prescribed in IEC EN 50399 in whose tests the heat emission, smoke production and possible dripping during the flame development test are also measured.
FS18OR18 cables are also non-flame propagating on the single vertical cable as per EN and IEC 60332-1-2 (IEC 20-35) tests. In addition, to prevent further hazards from substances emitted during combustion of plastics, FS18OR18 cables are made of special halogen-reduced compounds with amounts of hydrochloric acid, contained in the fumes emitted during combustion, less than 18%. FS18OR18 cables belong to the ecological line called ECOGAMMA marked by the Windmill symbol. In these environmentally friendly cables, lead, a heavy metal that is dangerous to the environment and to humans if present in excessive quantities, has been eliminated.
Data sheet
- Type:
- FS18OR18
- Cross-Section:
- 1mmq
- With yellow/green:
- No
- Number of cables:
- 4