CPR cable FS18OR18 3 G 1 mmq 300/500V Cca-s3 d1 a3

CPR cable FS18OR18 3 G 1,5 mmq 450/750V Cca-s3 d1 a3


9X9 FS18OR183GV750 8032877447024

CPR cable FS18OR18 3 G 1,5 mmq 450/750V (replaces the old Fror) Cable for energy, signalling and control, PVC insulated of quality S18 under PVC sheath of quality R18, with particular characteristics of reaction to fire and responding to the Regulation Products for Construction CPR (EU) n°305/11.

The producers of our cables are:

  • Baldassari cavi
  • Icel
  • La Triveneta
  • Prysmian
The delivery of the cable from one manufacturer rather than another is dictated by the availability of the moment. All our cables comply with the relevant legal regulations.  
The right of withdrawal does not apply to this product as the cables are cut according to your personal specifications.
Do you have questions about this product or did you not find what you were looking for? Ask us!
CPR cable FS18OR18 3 G 1 mmq 300/500V Cca-s3 d1 a3

CPR cable FS18OR18 3 G 1,5 mmq 450/750V Cca-s3 d1 a3

€0.77
€0.77

CPR cable FS18OR18 3 G 1,5 mmq 450/750V Cca-s3 d1 a3

€0.77
Tax included

CPR cable FS18OR18 3 G 1,5 mmq 450/750V Cca-s3 d1 a3

€0.77

Buy it within and receive it from Monday, 11 November
Two-year warranty

Suitable for fixed installation or for temporary installation in places with fire risk. For indoor use in dry or wet rooms (CEI 20-40).

Features:

  • Outer diameter 7.6 mm
  • Conductor Flexible wire of annealed red copper, class 5
  • Insulation PVC compound, S18 quality
  • Outer sheath Compound of PVC quality R18
  • Colour Energy cores (from 2 to 5 conductors): coloured cores according to CEI UNEL 00722 or numbered in black with or without protective conductor
  • Signalling and control (>5 cores): black colour with progressive numbering according to CEI UNEL 00722 with or without protective conductor
  • Sheath colour Brown
  • Rated voltage Uo/U: 450/750V
  • Maximum working temperature: 70°C
  • Minimum operating temperature: -15°C (in the absence of mechanical stress)
  • Minimum installation temperature: 0°C
  • Maximum short circuit temperature: 160°C
  • Maximum tensile stress: 50 N/mm2
  • Minimum bending radius: 4 times the maximum outer diameter

FS18OR18 cables belong to the AFIAM range and are marked Cca-s3,d1,a3, to indicate that they comply with the Construction Products Regulation (CPR) in accordance with the requirements set out in EN 50575:2014+A1:2016 and to indicate that they are fire retardant in accordance with the self-extinguishing requirements set out in standard CEI EN 50399 in which tests are also measured for heat emission, smoke production and possible dripping during the flame development test.

FS18OR18 cables are also flame retardant on the single vertical cable as per EN and IEC 60332-1-2 (CEI 20-35) tests. In order to prevent further risks deriving from the substances emitted during the combustion of plastic materials, FS18OR18 cables are manufactured with special compounds with reduced emission of halogens, with a quantity of hydrochloric acid, contained in the fumes emitted in case of combustion, lower than 18%. FS18OR18 cables belong to the ecological line called ECOGAMMA marked by the symbol of the Windmill. In these ecological cables, lead has been eliminated, a heavy metal, dangerous for the environment and for man if present in excessive quantities.

Data sheet

Type:
FS18OR18
Cross-Section:
1.5mmq
With yellow/green:
No
Number of cables:
3