CPR FS18OR18 3 G 2.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
CPR FS18OR18 3 G 2.5 sq. mm cable with Yellow/Green flame retardant with the following characteristics:
- Sheath Color : Brown
- Cable Diameter : 7.6 mm
- Insulation Class : 450/750V
- Conductor : flexible cord of annealed red copper, class 5
- Insulation Compound of PVC quality S18
- Maximum tensile stress : 50 N/mm2
- Minimum bending radius: 4 times the maximum outer diameter
100-meter skein.
- Baldassari cavi
- Icel
- La Triveneta
- Prysmian
CPR FS18OR18 3 G 2.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
CPR FS18OR18 3 G 2.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
The minimum purchase order quantity for the product is 100.
Tax included
CPR FS18OR18 3 G 2.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
The minimum purchase order quantity for the product is 100.
FS18OR18 cables belong to the AFIAM line and are marked Cca-s3,d1,a3, to indicate that they are compliant with the Construction Products Regulation (CPR) in accordance with the requirements prescribed in EN 50575:2014+A1:2016 and to indicate that they are of the non-fire-propagating type in accordance with the self-extinguishing requirements prescribed in IEC EN 50399 in whose tests heat emission, smoke production and possible dripping during the flame development test are also measured.
FS18OR18 cables are also flame-retardant on the single vertical cable as per EN and IEC 60332-1-2 (IEC 20-35) tests. In addition, in order to prevent further risks from substances emitted during combustion of plastics, FS18OR18 cables are made of special halogen-reduced compounds, with the amount of hydrochloric acid, contained in the fumes emitted during combustion, less than 18%. FS18OR18 cables belong to the ecological line called ECOGAMMA marked by the Windmill symbol. Lead, a heavy metal that is dangerous to the environment and humans if present in excessive quantities, has been eliminated in these environmentally friendly cables.
Suitable for fixed installation or temporary installation in places with fire hazards. For indoor use in dry or wet rooms (IEC 20-40).
Characteristics:
- Outer diameter 7.6 mm
- Conductor Flexible annealed red copper cord, class 5
- Insulation S18-quality PVC compound
- Outer sheath R18-quality PVC compound
- Sheath color Brown
- Rated voltage Uo/U: 450/750 V
- Maximum operating temperature: 70°C
- Minimum operating temperature: -15°C (in the absence of mechanical stress)
- Minimum installation temperature: 0°C
- Maximum short circuit temperature: 160°C
- Maximum tensile stress: 50 N/mm2
- Minimum bending radius: 4 times the maximum outer diameter
Data sheet
- Type:
- FS18OR18
- Cross-Section:
- 2.5 mmq
- With yellow/green:
- Yes
- Number of cables:
- 3