CPR FS18OR18 4 G 1.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
CPR FS18OR18 4 G 1.5 sq. mm cable with Yellow/Green flame-retardant with the following characteristics:
- Diameter : 7.6 mm
- Sheath Color : Brown
- Insulation Class : 450/750V
- Conductor: flexible rope of annealed red copper, class 5
- Insulation Compound of PVC quality S18
- Maximum tensile stress : 50 N/mm2
- Minimum bending radius: 4 times the maximum outer diameter
100-meter skein.
- Baldassari cavi
- Icel
- La Triveneta
- Prysmian
CPR FS18OR18 4 G 1.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
CPR FS18OR18 4 G 1.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
The minimum purchase order quantity for the product is 100.
Tax included
CPR FS18OR18 4 G 1.5 mmq 450/750V cable with G/V flame retardant hank 100 meters
The minimum purchase order quantity for the product is 100.
FS18OR18 cables belong to the AFIAM line and are marked Cca-s3,d1,a3, to indicate that they are compliant with the Construction Products Regulation (CPR) in accordance with the requirements prescribed in EN 50575:2014+A1:2016 and to indicate that they are of the non-fire-propagating type in accordance with the self-extinguishing requirements prescribed in IEC EN 50399 in whose tests heat emission, smoke production and possible dripping during the flame development test are also measured.
FS18OR18 cables are also non-flame propagating on the single vertical cable as per EN and IEC 60332-1-2 (IEC 20-35) tests. In addition, to prevent further hazards from substances emitted during combustion of plastics, FS18OR18 cables are made of special halogen-reduced compounds with amounts of hydrochloric acid, contained in the fumes emitted during combustion, less than 18%.
FS18OR18 cables belong to the ecological line called ECOGAMMA marked by the Windmill symbol. In these environmentally friendly cables, lead, a heavy metal that is dangerous to the environment and to humans if present in excessive quantities, has been eliminated.
Features:
- Conductor Flexible annealed red copper cord, class 5
- Insulation S18-quality PVC compound
- Outer sheath R18-quality PVC compound
- Sheath color Brown
- Rated voltage Uo/U: 450/750 V
- Maximum operating temperature: 70°C
- Minimum operating temperature: -15°C (in the absence of mechanical stress)
- Minimum laying temperature: 0°C
- Maximum short circuit temperature: 160°C
- Maximum tensile stress: 50 N/mm2
- Minimum bending radius: 4 times the maximum outer diameter
- Application: Suitable for fixed laying or temporary installation in places with fire hazard
- For indoor use in dry or wet rooms. (ref. IEC 20-40)
Data sheet
- Type:
- FS18OR18
- Cross-Section:
- 1.5mmq
- With yellow/green:
- Yes
- Number of cables:
- 4