Best seller

Chint Residual Current Operated Circuit Breaker NB1L1 16A 1P+N 4.5KA 30MA A 2 Modules 203335


CHT 203335 6901800496632

Chint NB1L1 Residual Current Operated Circuit Breaker with the following characteristics:

 

  • Number of Poles: 1P+N
  • Rated current: 16A
  • Type: A
  • Curve C
  • Rated differential current: 30 mA
  • Rated breaking capacity: 4.5 kA
  • Rated voltage: 230 Vac
  • Number of Modules: 2
  • Degree of protection: IP20
Do you have questions about this product or did you not find what you were looking for? Ask us!

Chint Residual Current Operated Circuit Breaker NB1L1 16A 1P+N 4.5KA 30MA A 2 Modules 203335

€23.98
€23.98

Chint Residual Current Operated Circuit Breaker NB1L1 16A 1P+N 4.5KA 30MA A 2 Modules 203335

€23.98
Tax included

Chint Residual Current Operated Circuit Breaker NB1L1 16A 1P+N 4.5KA 30MA A 2 Modules 203335

€23.98

Buy it within and receive it from Thursday, 19 December
Two-year warranty
Easy return within 14 days

The Residual Current Operated Circuit Breaker  is located next to the circuit breaker and integrates a magnetic protection to a thermal one, and in case of need it interrupts the electric current. The thermal-magnetic circuit breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal features.

 

The Residual Current Operated Circuit Breaker in the electrical system integrates three different protections:

  • The magnetic one for short circuits that can endanger an entire building with the danger of fire
  • The thermal one for overloads in the supply of electricity (for example, more than one appliance in operation)
  • The differential one proper to the earth leakage circuit breaker, which protects the subject from a current leakage

     

The Residual Current Operated Circuit Breaker type A tripping is ensured for alternating sine differential currents and unidirectional pulsating differential currents applied suddenly or slowly increasing (IEC 61008-1).

 

NB1L1 series 4.5 kA magnetothermal/differential circuit breakers. Particularly suitable for line protection against overloads and short circuits, as well as against direct contacts. Intended for civil, tertiary and industrial applications.

 

Features:

  • Reference standard: IEC/EN 61009-1
  • Number of Poles: 1P+N
  • Rated current: 16 A
  • Tripping curve: C
  • Rated voltage: 230 Vac
  • Rated frequency: 50/60 Hz
  • Isolation voltage: 500 Vac
  • Impulse voltage: 6 kv
  • Rated breaking capacity: 4.5 kA
  • Extreme breaking capacity: 6 kA
  • Rated service interrupting capacity: 4.5 kA
  • Power Dissipation: 4.9 W
  • Number of DIN modules (1 DIN = 18 mm): 2
  • Degree of protection: IP20
  • Dimensions: 86x36x77 mm (HxWxD)

Data sheet

Voltage:
230VAC
Modules:
2
Poles:
1P+N
Curve:
C
Breaking capacity:
4.5KA
RCD Type:
A
Differential current :
0.03A
Degree of protection:
IP20
Amps:
16A
Circuit Protections:
RCBO