Abb Circuit breaker S304P 16A 4P 25KA C 4 Modules S304PC16


ABB S304PC16 4016779076456

Abb series S304P circuit breaker:

 

  • 16A rated current
  • 4 Poles
  • Rated short-circuit capacity 25KA
  • Type C
  • 4 Modules
  • Rated operating voltage: 415V
Do you have questions about this product or did you not find what you were looking for? Ask us!

Abb Circuit breaker S304P 16A 4P 25KA C 4 Modules S304PC16

€109.90
€109.90

Abb Circuit breaker S304P 16A 4P 25KA C 4 Modules S304PC16

€109.90
Tax included

Abb Circuit breaker S304P 16A 4P 25KA C 4 Modules S304PC16

€109.90

Buy it within and receive it from Monday, 30 December
Two-year warranty
Easy return within 14 days

Trip indicator The magnetothermal trip indicator window allows the cause of the trip to be identified directly on the circuit breaker: short circuit, overload, xxx, etc., or manual operation.

 

 

S304P series circuit breakers provide protection in industrial plants against overloads and short circuits. This product is manufactured to IEC and UL international standards for markets where it is required.

 

Curve C can tolerate short-time overcurrents up to five to ten times the rated current and is widely used in domestic installations.

 

A circuit breaker is a safety device that can automatically (i.e., without external intervention) interrupt the flow of electric current in an electrical circuit in the event of an overcurrent.

 

Features:

  • Certificates: Standard: CSA 22.2 No. 235 - IEC/EN 60898-1 standard - IEC/EN 60947-2 standard -UL 1077
  • Tripping characteristic: C
  • Rated operating voltage: according to IEC 60898-1 415 V AC - according to IEC 60898-1 415 V - according to IEC 60947-2 415 V AC
  • Operating voltage: Maximum (Including Tolerance) 457 V AC - Maximum 457 V AC - Minimum 12 V AC - Minimum 12 V DC
  • Rated insulation voltage (Ui): according to IEC/EN 60664-1 500 V
  • Impulse withstand voltage (Uimp): 6 kV
  • Dielectric proof voltage: 50/60 Hz, 1 minute: 2 kV
  • Input voltage type: alternating current/direct current
  • Rated current (In): 16 A
  • Rated short-circuit capacity: (AC) 25 kA - (400 V) 25 kA
  • Rated extreme short-circuit capacity (Icu): (415 V AC) 25 kA - (440 V AC) 15 kA - (400 V) 25 kA
  • Rated frequency (f): 50/60 Hz frequency
  • Power Loss: 6.8 W at Rated Operating Conditions per pole 1.7 W
  • Power supply voltage connection: Arbitrary
  • Contact position indication: Red ON / Green OFF
  • Electrical resistance: 20000 AC cycle(s)
  • Mechanical resistance: 20000 cycle (i)
  • Number of poles protected: 4
  • Number of poles: 4
  • Overvoltage category: IV
  • Tightening torque: 2.8 N-m
  • Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
  • Actuator Marking: I / O
  • Actuator Material: Insulation Group II, Black, Sealable
  • Enclosure Material: Insulation Group I, RAL 7035
  • DIN Rail Mounting: TH35-15 (35 x 15 mm Mounting Rail) according to IEC 60715 - TH35-7.5 (35 x 7.5 mm Mounting Rail) according to IEC 60715
  • Mounting position: any
  • Recommended Screwdriver: Pozidriv 2
  • Accessories Available: Yes
  • Connection Capacity: Busbar 10 / 10 mm² - Flexible with Ferrule 0.75 ... 25 mm² - Flexible 0.75 ... 25 mm² - Flexible 0.75 ... 25 mm² - Rigid 0.75 ... 35 mm² - Stranded 0.75 ... 35 mm²
  • Installation dimensions: according to DIN 43880 1
  • Width in number of modular intervals: 4.0
  • Product width: 70 mm
  • Product height: 88 mm
  • Product depth: 69 mm
  • Product net weight: 0.496 kg
  • Pole net weight: 0.124 kg
  • Built-in depth (t2): 69 mm.

Data sheet

Voltage:
415VAC
Modules:
4
Poles:
4P
Curve:
C
Breaking capacity:
25KA
Degree of protection:
IP20
Amps:
16A
Circuit Protections:
Circuit breakers