Double Insulated Flameproof Cable FG16OR16 4x1.5 sq. mm with G/V


9X9 FG16R4G1,5M

Double Insulation Flame-retardant FG16OR16 4x1.5 sq mm 0.6/1 kV cable with Yellow/Green with the following characteristics:

 

  • Outer diameter: 11.2 mm
  • Conductor diameter: 1.6 mm
  • Insulation thickness: 0.7 mm
  • Sheath thickness: 1.8 mm
  • Electrical resistance: 13.3 ohm/km
  • Current carrying capacity tube in air: 19.5 A
  • Current carrying capacity in buried pipe: 19 A

     

Sale by the meter.

The producers of our cables are:

  • Baldassari cavi
  • Icel
  • La Triveneta
  • Prysmian
The delivery of the cable from one manufacturer rather than another is dictated by the availability of the moment. All our cables comply with the relevant legal regulations.  
The right of withdrawal does not apply to this product as the cables are cut according to your personal specifications.
Do you have questions about this product or did you not find what you were looking for? Ask us!

Double Insulated Flameproof Cable FG16OR16 4x1.5 sq. mm with G/V

€1.29
€1.29

Double Insulated Flameproof Cable FG16OR16 4x1.5 sq. mm with G/V

€1.29
Tax included

Double Insulated Flameproof Cable FG16OR16 4x1.5 sq. mm with G/V

€1.29

Buy it within and receive it from Monday, 11 November
Two-year warranty

Multi-core energy cable insulated with high-modulus ethylene-propylene rubber of G16 quality, under PVC sheath, with special fire reaction characteristics and complying with the Construction Products Regulation (CPR).

 

Features:

  • Conductor: Flexible annealed red copper cord, class 5
  • Insulation: High-modulus ethylpropylene rubber compound of G16 quality
  • Filler: Compound of non-hygroscopic material
  • Outer sheath: PVC compound of R16 quality
  • Sheath color: Gray
  • Rated voltage Uo/U: 0.6/1 kV
  • Maximum operating temperature: 90°C
  • Minimum operating temperature: -15°C (in the absence of mechanical stress)
  • Minimum laying temperature: 0°C
  • Maximum short-circuit temperature: 250°C up to 240 mm² section, over 220°C
  • Maximum tensile stress: 50 N/mm2
  • Minimum bending radius: 4 times the maximum outer diameter

     

Conditions of use: Cables suitable for power supply in buildings and other civil engineering works with the aim of limiting the production and spread of fire and smoke. For use indoors in even wet rooms or outdoors (AD7). Suitable for fixed installation on masonry and metal structures in free air, in pipe or duct or similar systems. Also permitted for underground installation. Good resistance to industrial oils and greases.

Data sheet

Colour:
Grey
Cross-Section:
1.5mmq
With yellow/green:
Yes
Number of cables:
4