Beta Cavi fire resistant cable 2x1.5 sq. mm LSZH sheath Red 500m
Fire-resistant shielded cable for fixed automatic fire detection and fire alarm signaling systems Beta Cavi FTE29OHM16 with the following characteristics:
- PH circuit integrity: PH120
- Formation: 2x1.5 sq. mm
- Pair capacitance: 67 pF/m
- Resistance: 13.2 DC /KM
- Outer diameter: 8.20 mm
- LSZH Sheath Red
- Fire Reaction Classification: Cca s1b, d1, a1
- Installation: Indoor and Outdoor
The selling price is intended per meter.
Minimum saleable quantity: hank of 500 meters.
Beta Cavi fire resistant cable 2x1.5 sq. mm LSZH sheath Red 500m
Beta Cavi fire resistant cable 2x1.5 sq. mm LSZH sheath Red 500m
The minimum purchase order quantity for the product is 500.
Tax included
Beta Cavi fire resistant cable 2x1.5 sq. mm LSZH sheath Red 500m
The minimum purchase order quantity for the product is 500.
Following the latest regulatory developments, the cables used in a fire detection and alarm signaling system will necessarily have to comply with the new product standard CEI 20-105V2, the test methodology CEI EN 50200 and the EU regulation 305:2011 according to Euroclass Cca s1b d1 a1.
These characteristics guarantee not only the maintenance of the functionality of the system under fire conditions, but also the safety for the people present according to the new indications introduced by the CPR regulation.
A cable that complies with CEI EN 50200 test methodology, ensures the functionality of the loop during the test for a given period of time (a requirement of uni 9795 PH30) but, as a test method, does not provide indications regarding the construction characteristics i.e. the electrical, transmission and mechanical parameters.
The fire loop is a BUS-type connection on which runs a digital protocol for communication between apparatuses, therefore, if the real need of the manufacturers of apparatuses for fire detection systems is to connect the system with cables with specific electrical performance in addition to ensuring fire resistance for a given period of time, it is the responsibility of the individual manufacturers to indicate, in addition to fire resistance, the requirements necessary for the proper functioning of the system such as two-point shielding, capacitance, inductance, etc. in order to avoid malfunctions.
Characteristics:
- CPR classification Cca s1b, d1, a1
- Use with apparatus having operating voltages not exceeding 100 VAC
- Connection between: control panel and detection points, electro locks, natural smoke and heat evacuators, electromagnets for fire door release
- Cable for CAT I systems
- Rated operating voltage Uo/U= 100/100V
- Rated insulation voltage Uo= 400V
- Suitable for laying in coexistence with cables for category I systems (e.g., 230V, 400V)
- Outer sheathing made of Duraflam LSZH red
- Inner insulation color: 2 conductors red and black
Data sheet
- Colour:
- Red
- Diameter:
- 8,2mm
- Type:
- Fire-resistant Cables
- Cross-Section:
- 1.5mmq
- With yellow/green:
- No
- Number of cables:
- 2