ABB Residual Current Operated Circuit Breaker 1P+N 16A 30mA A 4.5kA 1M DS301CLC16A30


ABB DS301CLC16A30 8012542364054

ABB Residual Current Operated Circuit Breaker with the following characteristics:

 

  • Number of poles: 1P+N
  • 16 Amps
  • Differential current Idn 30mA
  • A type
  • Interrupting capacity: 4.5kA
  • Number of modules: 1
  • C curve
Request info about this product

ABB Residual Current Operated Circuit Breaker 1P+N 16A 30mA A 4.5kA 1M DS301CLC16A30

€42.47
€42.47

ABB Residual Current Operated Circuit Breaker 1P+N 16A 30mA A 4.5kA 1M DS301CLC16A30

€42.47
Tax included
klarna Pay in installments with Klarna
qty

ABB Residual Current Operated Circuit Breaker 1P+N 16A 30mA A 4.5kA 1M DS301CLC16A30

€42.47

Buy it within and receive it from Thursday, 4 July
Two-year warranty
Secure Payment
Easy return within 14 days

DS301 C L is the range of slim Residual Current Operated Circuit Breaker in 1 module. Due to the compact size of the circuit breaker, space can be saved inside the switchboard by accommodating more circuits, thus ensuring better selectivity of the system. Alternatively, it is possible to reduce the size of the residential switchboard (compared with using the same number of differential circuit breakers in two modules).


 

The Residual Current Operated Circuit Breaker is located next to the circuit breaker and integrates a magnetic protection to a thermal one and interrupts the electric current in case of need. The thermal-magnetic circuit breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal features.


 

The Residual Current Operated Circuit Breaker in the electrical system integrates three different protections:

  • the magnetic one for short circuits that can endanger an entire building with the danger of fire
  • the thermal one for overloads in the supply of electricity (for example, more than one appliance in operation)
  • the differential one proper to the circuit breaker, which protects the subject from a leakage of current


     

The C curve, trip threshold of 5 to 10 times In, for application of ohmic-inductive circuits with medium inrush currents. And widely used in domestic systems.


 

The A type circuit breaker the tripping is assured for suddenly or slowly increasing applied sinusoidal alternating differential currents (IEC EN 61008-1).


 

Features:

  • Abb series
  • Voltage 230 Vac
  • Tripping curve C
  • Rated frequency 50Hz
  • Degree of protection according to EN 60529 enclosure IP4X terminals IP2X
  • Enclosure Insulation group I - II, RAL 7035
  • Control lever Insulation group II, black plumbable in ON-OFF position
  • CPI contact position indicators (green/red)
  • Differential trip indicator differential trip indicator (blue)
  • Ambient temperature (with daily average +35 °C) -25/+55 degrees
  • Storage temperature: -40/+70 degrees

Data sheet

Modules:
1
Poles:
1P+N
Curve:
C
Breaking capacity:
4.5KA
RCD Type:
A
Differential current :
0.03A
Amps:
16A
Circuit Protections:
RCBO