Abb Moulded Case Circuit Breaker XT1B 160 3X125A+N/2 18KA XT1B125TMD4
ABB XT1B125TMD4
8015644007263
Abb XT1B 3X125A+N/2 18KA fixed tetrapolar moulded circuit breaker with thermomagnetic front terminals TMD R 125-1250A neutral = 50% phases.
Abb Moulded Case Circuit Breaker XT1B 160 3X125A+N/2 18KA XT1B125TMD4
€369.93
€369.93
Abb Moulded Case Circuit Breaker XT1B 160 3X125A+N/2 18KA XT1B125TMD4
€369.93
Tax included
Tax included
Items Available: 3
Abb Moulded Case Circuit Breaker XT1B 160 3X125A+N/2 18KA XT1B125TMD4
€369.93
Buy it within and receive it from Monday, 30 December
Frequently bought together
Features:
- Product width: 101.6 mm
- Product height: 130 mm
- Product depth: 70 mm
- Product net weight: 1.4 kg
- Type of switch to be associated with: Power Distribution
- Main product type: SACE Tmax XT
- Product Name: Molded Case Circuit Breaker
- Product type: Automatic Circuit Breaker
- Version: F
- Cable cross-sections-main circuit: Busbar 45.5 ... 80 mm²
- Current Type: AC/DC
- Electrical life: 120 cycles per hour - 8000 cycle(s)
- Mechanical life: 240 cycles per hour - 25000 cycle(s)
- Number of poles: 4
- Opening time: CB with SOR 15 ms - CB with UVR 15 ms
- Multiple order: 1 piece(s)
- Power loss: at Rated Operating Conditions per pole 10.7 W
- Rated current (In): 125 A
- Rated Frequency (f): 50 / 60 Hz
- Impulse withstand voltage (Uimp): 8 kV
- Rated instantaneous short-circuit current setting (Ii): 1250 A
- Rated insulation voltage (Ui): 800 V
- Rated operating voltage: 690 V AC - 500 V DC
- Rated service short-circuit rating (Ics): (220 V AC) 25 kA - (230 V AC) 25 kA - (240 V AC) 25 kA - (380 V AC) 18 kA - (415 V AC) 18 kA - (440 V AC) 11.25 kA - (500 V AC) 8 kA - (525 V AC) 6 kA - (690 V AC) 3 kA - (250 V DC) 2 Poles in Series 18 kA - (500 V DC) 3 Poles in Series 18 kA
- Rated extreme short-circuit capacity (Icu): (220 V AC) 25 kA - (230 V AC) 25 kA - (240 V AC) 25 kA - (380 V AC) 18 kA - (415 V AC) 18 kA - (440 V AC) 15 kA - (500 V AC) 8 kA - (525 V AC) 6 kA - (690 V AC) 3 kA - (250 V DC) 2 Poles in Series 18 kA - (500 V DC) 3 Poles in Series 18 kA
- Rated uninterrupted current (Iu): 160 A
- Rated voltage (Ur): 690 V
- Recommended screwdriver: M6 Main Circuit
- Trip: TMD
- Trip type: TM
- Setting range: 87.5...125 A
- Short-circuit performance level: B
- Reference Standards: IEC60947-2
- Subtype: XT1
- Clamp connection type: Front
- Clamp type: Bolt
- Tightening torque: 6 N-m.
Data sheet
- Type: Switches
- Poles: 4P
- Breaking capacity: 18KA
- Amps: 125A