Abb Residual Current Operated Circuit Breaker 2 poles 6A 30mA AC type 6kA 2 modules DS202CRC6AC30


ABB DS202CRC6AC30 8012542141457

Abb Residual Current Operated Circuit Breaker, with the following characteristics:
 

  • Rated operating voltage: acc. to IEC 60898-1 230V
  • Rated insulation voltage (U i ): acc. to IEC/EN 60664-1 440V
  • Rated impulse withstand voltage (U imp ):4 kV
  • Tripping characteristic: C
  • Residual current type: AC type
  • Input voltage type: AC
  • Rated current (In ):6 amps
  • Rated residual current: 30 mA
  • Rated short-circuit capacity: 6 kA
  • Rated maximum short-circuit breaking capacity (I cu ): 10kA
  • Rated service short-circuit breaking capacity (Ics ): 6kA
  • Maximum peak current: 0.25kA
  • Leakage current type: AC
  • Frequency: 50Hz
Request info about this product

Abb Residual Current Operated Circuit Breaker 2 poles 6A 30mA AC type 6kA 2 modules DS202CRC6AC30

€67.94
€67.94

Abb Residual Current Operated Circuit Breaker 2 poles 6A 30mA AC type 6kA 2 modules DS202CRC6AC30

€67.94
Tax included
klarna Pay in installments with Klarna
qty

Abb Residual Current Operated Circuit Breaker 2 poles 6A 30mA AC type 6kA 2 modules DS202CRC6AC30

€67.94

Buy it within and receive it from Tuesday, 2 July
Two-year warranty
Secure Payment
Easy return within 14 days

The Residual Current Operated Circuit Breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal characteristics.


 

The Residual Current Operated Circuit Breaker in the electrical system integrates three different protections:
 

  • the magnetic one for short circuits that can endanger an entire building with the danger of fire;
  • the thermal one for overloads in the power supply (e.g., more than one appliance in operation);
  • that differential proper of the circuit breaker that protects the subject from a power leakage.
     


The AC type Residual Current Operated Circuit Breaker the tripping is ensured for suddenly or slowly increasing applied differential sinusoidal alternating currents (IEC EN 61008-1).


Features:

  • Abb series
  • Standard: CEI/EN 61009-1 - CEI/EN 61009-2-1
  • Rated frequency: 50Hz
  • Power loss: 3.04W
  • Power connection: Arbitrary
  • Energy class limit: 3
  • Electrical resistance:10000 operations
  • Mechanical endurance:20000 operations
  • 2 modules
  • Number of poles:2
  • Number of protected poles:2
  • Fault indication:Blue flag on the window
  • Operating characteristic:Instantaneous
  • Overvoltage category: III
  • Position of neutral terminals:Right Left
  • Tightening torque: 4 Nm
  • Type of accessory: Auxiliary contact
  • Signal/auxiliary contact
  • Ground disconnect type: Non-delayed
  • Ambient air temperature: Operating -5 /+55 °C - Storage -40 /+70 °C
  • Mounting type: on DIN rail EN 60715 (35mm) via mounting clip
  • Mounting position: Any
  • Cable size: 35mm²
  • Degree of protection: IP20
  • Pollution degree: 3
  • Environmental conditions: 28 cycles - with 55 °C / 90-96 % - and 25 °C / 95-100 %
  • Wire stripping length: 11mm
  • RoHS status: following EU Directive 2011/65/EU and Amendment 2015/863 of July 22, 2019
  • Net width of the product: 36 mm
  • Net height of the product: 86 mm
  • Net depth/length of product:72 mm
  • Net product weight:0.220 kg
  • Built-in depth ( t 2 ): 72 mm

Data sheet

Modules:
2
Poles:
2P
Curve:
C
Breaking capacity:
6KA
RCD Type:
AC
Differential current :
0.03A
Amps:
6A
Circuit Protections:
RCBO