Abb switchboard kit for protection of photovoltaic inverter AC 6kW


KIT ABBAC06

Abb switchboard kit for photovoltaic inverter protection AC 3kW consisting of:
 

  • 1 Mistral 65H wall-mounted switchboard with transparent door 8 modules H65P08X120750
  • 1 Residual current operated circuit breaker 6KA 2P A C32 300mA DS202CRC32A300
  • 1 Surge protector OVR T2+T3 1N 20-275P 1P+N 20KA OVR231N20275
  • 1 E 91HN/32 E90 Fuse holder 1P+N 32A M200913
With the kit you save compared to individually purchased items
Do you have questions about this product or did you not find what you were looking for? Ask us!

The kit includes:

Abb switchboard kit for protection of photovoltaic inverter AC 6kW

€245.98
€245.98

Abb switchboard kit for protection of photovoltaic inverter AC 6kW

€245.98
Tax included

Abb switchboard kit for protection of photovoltaic inverter AC 6kW

€245.98

Buy it within and receive it from Tuesday, 17 December
Two-year warranty
Easy return within 14 days

The framework solution kit for Abb side protection Inverter AC 3kW has the following advantages:

 

  • Mistral H series switchboard: Designed specifically for photovoltaic installations (UV resistant) and outdoor installation IP65 750° GWT
  • Circuit breaker type DS202CR: Compact differential magneto thermal switch in 2 modules with 300mA type A differential, suitable for AC side inverter protection
  • AC-side OVC Discharger: Type T2+T3 - 20 kA - Innovative Quicksave Technology.

 

Specifications of parts in the Kit:

 

 

Abb Mistral series wall-mounted switchboard with the following features:

 

  • Number of modules: 8
  • Number of rows: 1
  • Type of mounting: Surface mounting (plaster)
  • Enclosure material: Plastic
  • Degree of protection: IP65
  • Color: Gray
  • Product width: 232 mm
  • Product height: 155 mm
  • Product depth: 250 mm
  • Product net weight: 1.1 kg


 

Residual current operated circuit breaker DS202CR C32 A300 Abb with overcurrent protection with the following features:
 

  • Rated current: 32A
  • Rated residual current: 300 mA
  • Rated short-circuit capacity: 6 kA
  • Number of poles: 2
  • Input voltage type: AC
  • Tripping characteristic: C
  • Degree of protection: IP20
  • Number of modules: 2


 

2P device in two modules for protection of single-phase end-user circuits from overloads and short-circuit currents. Protection against the effects of direct alternating sinusoidal and pulsating earth fault currents. Protection against indirect contacts and additional protection against direct contacts.

2P device in two modules for protection of single-phase circuits of end users against overloads and short-circuit currents. Protection against the effects of direct alternating sinusoidal and pulsating ground fault currents. Protection against indirect contacts and additional protection against direct contacts.

 

Curve C, trip threshold from 5 to 10 times In, for application of ohmic-inductive circuits with medium inrush currents. And widely used in domestic installations.

 

A circuit breaker is a safety device that can automatically (i.e., without external intervention) interrupt the flow of electric current in an electrical circuit in the event of an overcurrent.

 

Characteristics:

 

  • Rated current: 32A
  • Rated residual current: 300 mA
  • Rated short-circuit capacity: 6 kA
  • Number of poles: 2
  • Input voltage type: AC
  • Tripping characteristic: C
  • Degree of protection: IP20
  • Number of modules: 2
  • Rated operating voltage: 230 V
  • Rated insulation voltage: 440 V
  • Impulse withstand voltage: 4 kV
  • Rated extreme short-circuit capacity: 10 kA
  • Maximum peak current: 0.25 kA
  • Rated frequency: 50 Hz
  • Power loss: 7.60 W
  • Energy limitation class: 3
  • Overvoltage category: III
  • Tightening torque: 4 Nm
  • Cable size: 35 mm²
  • Cable stripping length: 11 mm
  • Ambient temperature: In operation -25/+55 degrees
  • Pollution degree: 3
  • Width: 36 mm
  • Height: 86 mm
  • Depth: 72 mm

 

Abb OVR T2-T3 1N 20-275P QS surge protector with the following characteristics:
 

  • Short-circuit rating: 20 kA
  • Rated service short-circuit capacity (Ics): 100kA
  • Rated voltage: 230/400V
  • Number of poles: 1P+N
  • Degree of protection: IP20
  • Power loss: 17 mW
  • Number of modules: 2

     

Type 2 surge protectors are suitable for installation at the origin of the system, in intermediate switchboards and near terminal equipment, and protect against indirect lightning strikes.

 

Characteristics:

 

  • Short-circuit rating: 20 kA
  • Rated service short-circuit capacity (Ics): 100kA
  • Rated voltage: 230/400V
  • Number of poles: 1P+N
  • Degree of protection: IP20
  • Power loss: 17 mW
  • Number of modules: 2
  • Suitable for: To protect systems from transient overvoltages (lightning)
  • Rated voltage (Ur): 400 V AC
  • Rated AC system voltage (Uo): 230 / 400 V
  • Rated DC voltage: 350 V
  • Voltage protection level ( Up): 1.4 kV
  • Rated service short circuit rating (Ics): 100kA
  • Short-circuit withstand Icc: 100kA
  • Power loss: 17 mW
  • Width: 35.6 mm
  • Height: 88mm
  • Depth: 58mm

 

 

Abb fuse holder, with the following features:

  • 1 pole +N
  • 1 module
  • Rated current 32A
  • Rated frequency 50/60 Hz
  • Rated operating voltage 690Vac
  • Rated voltage 690V
  • Voltage range 690 Vac
  • Right neutral terminal location
  • Power loss at rated operating conditions per pole 3W
  • Degree of protection IP20
  • For fuse size 10x38 mm
  • DIN rail mounting
  • Width 0.018 mm
  • Height 0.085 mm
  • Depth/Length 0.064 mm
  • Weight 0.070 kg

Data sheet

KIT:
Distributions boards-Kits