Vaillant ecoTEC pure VMW Natural gas condensing boiler 7.25/24 kW 0010019985


VLT 0010019985 4024074788653

Vaillant ecoTEC pure VMW natural gas condensing boiler with the following characteristics:

 

  • Erp Energy Class Heating - Water: A-A
  • Min-max heating output: 7.5 - 24.0 kW
  • Min-max DHW output: 7.0 - 28.0 kW
  • Withdrawal flow rate (T = 30K): 13.5 l/min
  • Temperature regulation: 35-60 degrees
  • Flue gas connection diameter: 60 100 mm
  • Possible flue gas outlet diameter: 60/100 - 80/125 - 80/80 - 60/60 mm
  • Gas-water connections: 1/2 3/4
  • Dimensions: 720x440x335 mm ( H-L-P)

     

Features:

  • Stainless steel exchanger
  • Pneumatic combustion system
  • Modulation 1:4
  • Expansion tank 8 liters
  • Instantaneous acs production
  • Vertical hydraulic connections
  • Possibility of installation in partially covered place up to 0° C
  • tagav
  • Do you have questions about this product or did you not find what you were looking for? Ask us!

    Vaillant ecoTEC pure VMW Natural gas condensing boiler 7.25/24 kW 0010019985

    €1,352.63
    €1,352.63

    Vaillant ecoTEC pure VMW Natural gas condensing boiler 7.25/24 kW 0010019985

    €1,352.63
    Tax included

    Vaillant ecoTEC pure VMW Natural gas condensing boiler 7.25/24 kW 0010019985

    €1,352.63

    Buy it within and receive it from Friday, 13 December
    Two-year warranty
    Easy return within 14 days

    The new design of ecoTEC pure immediately recalls the quality and reliability that characterizes Vaillant's DNA. Indoor condensing boiler with standard Vaillant measurements 72 cm high, 44 cm wide and 33 cm deep.

     

    EcoTEC pure is the ideal solution for anyone who wants to switch to Vaillant with no worries because it is equipped with vertical connections that make it quick and easy to install.Vaillant quality guarantees low consumption and good energy efficiency: the boiler is class A in both heating and DHW.

     

    The pure range consists of a single natural gas model with combined production. A kit allows switching to propane and propane air supply. The boiler features a new thermohydraulic module equipped with a modulating pump to ensure low electricity consumption while a new stainless steel exchanger and a wide modulation range of up to 1:4 ensure gas savings.

     

    EcoTEC pure is the range dedicated to replacements of boilers of other brands, possible thanks to the simplicity of vertical connections and ease of use.


     

    Ease of operation thanks to a highly simplified set of controls and display, suitable for all types of customers. Vaillant has found an innovative solution to prevent freezing of the condensate siphon, the element most sensitive to frost, and thanks to the ecoLEVEL accessory it is possible to channel the condensate into the appropriate drains.

     

    The boiler mounts a new high-efficiency pump with high performance, a stainless steel exchanger and an 8-liter expansion tank.

     

    General data:

    • Gas category: II2HM3P
    • Gas pipe diameter: 1/2
    • Heating pipe diameter: 3/4
    • Hot water pipe diameter: 3/4
    • Safety valve connection pipe: 15 mm
    • Condensate drain pipe: 21.5 mm
    • G20 gas supply pressure: 2.0 kPa (20.0 mbar)
    • G230 gas supply pressure: 2.0 kPa (20.0 mbar)
    • G31 gas supply pressure: 3.7 kPa (37.0 mbar)
    • Gas flow rate with P max. Domestic hot water (G20): 3.0 m³/h
    • Gas volumetric flow rate for P max. - Domestic hot water (G230): 2.09 m³/h
    • Gas volumetric flow rate for P max. - domestic hot water (G31): 2.09 m³/h
    • Flue gas mass flow rate in heating mode operation at P min: 3.7 g/s
    • Flue gas mass flow rate in heating mode operation at P max: 11.8 g/s
    • Flue gas mass flow rate in hot water mode operation at P max: 13.6 g/s
    • Flue gas temperature min. 41
    • Flue gas temperature max. 95
    • Nominal efficiency at 80/60 °C 97.0 %.
    • Nominal efficiency at 50/30 °C 105.4 %

       
    Gas and domestic water connections:
    • Heating flow connection, G3/4
    • Hot water pipe connection, G3/4
    • Cold water pipe connection, G3/4
    • Heating return connection, G3/4
    • Gas connection G1/2

    G20 technical data:

    • Useful power range (P) at 50/30 °C: 8.3 26.1 kW
    • Useful power range (P) at 80/60 °C: 7.5 24.0 kW
    • Useful power range - Domestic hot water or supplementary storage tank heating (P): 7.7 28.0 kW
    • Maximum heat output range - Heating (Q max.): 24.8 kW
    • Minimum heat output range - Heating (Q min.): 7.8 kW
    • Maximum heat flow rate Domestic hot water or supplementary storage tank heating (Q max.): 28.6 kW
    • Minimum heat flow rate - Domestic hot water or supplementary storage tank heating (Q min.): 7.8 kW

       

    Technical data - G230:

    • Useful power range (P) at 50/30 °C: 8.3 26.1 kW
    • Useful power range (P) at 80/60 °C: 7.5 24.0 kW
    • Useful power range - Domestic hot water or supplementary storage tank heating (P): 7.7 28.0 kW
    • Maximum heat output range - Heating (Q max.): 24.8 kW
    • Minimum heat output range - Heating (Q min.): 7.8 kW
    • Maximum heat flow rate Domestic hot water or supplementary storage tank heating (Q max.): 28.6 kW
    • Minimum heat flow rate - Domestic hot water or supplementary storage tank heating (Q min.): 7.8 kW

       

    Technical data - G31:

    • Useful power range (P) at 50/30 °C: 8.3 26.1 kW
    • Useful power range (P) at 80/60 °C: 7.5 24.0 kW
    • Useful power range - Domestic hot water or supplementary storage tank heating (P): 7.7 28.0 kW
    • Maximum heat output range - Heating (Q max.): 24.8 kW
    • Minimum heat output range - Heating (Q min.): 7.8 kW
    • Maximum heat flow rate Domestic hot water or supplementary storage tank heating (Q max.): 28.6 kW
    • Minimum heat flow rate - Domestic hot water or supplementary storage tank heating (Q min.): 7.8 kW

       

    Heating technical data:

    • Maximum flow temperature: 85
    • Max. flow temperature setting range (factory setting 75 °C): 30 80
    • Maximum allowable pressure (PMS): 0.3 Mpa (3.0 bar)
    • Nominal water flow rate (T = 20 K): 1,033 l/h
    • P heating with rated flow rate (?T = 20 K), by-pass closed: 0.014 Mpa
    • P heating with rated flow rate (?T = 20 K), by-pass in factory-set position: 0.025 Mpa
    • Approximate value of condensate flow rate (pH value between 3.5 and 4.0) at 50/30 °C: 2.48 l/h
    • Expansion tank content: 8.0 l

       

    Technical data - Domestic hot water:

    • Minimum water flow rate: 1.7 l/min
    • Specific flow rate (D) (?T = 30 K) according to EN 13203: 13.5 l/min
    • Specific flow rate (?T = 35 K): 11.6 l/min
    • Minimum allowable pressure: 0.03 Mpa (0.30 bar)
    • Maximum allowable pressure (PMW): 1 Mpa (10 bar)
    • Temperature range: 35 60
    • Flow rate limiter for cold water: 10.0 l/min

       

    Electrical system technical data:

    • Electrical connection: 230 V 50 Hz
    • Fuse fitted (delayed): T2/2A,250V
    • Electrical power consumption, max: 110 W
    • Standby electrical power consumption: 1.8 W
    • Type of protection: IPX4D
    • Allowable connection voltage: 190 253V

    Data sheet

    Type:
    Boilers
    Model:
    Natural gas
    Thermal power:
    24 kW
    Energy class:
    A
    Series:
    EcoTEC Pure